SGM-SF_2017with 12/20 Revisions
All Systems (revised 12/20) 32 ANSI/AARST SGM-SF 2017 (with 1220 revisions) Soil Gas Mitigation Standards for Existing Homes The primary label titles shall portray the system purpose, such as “Radon Reduction System” or "Soil Gas Control System." Information required on, or in immediate proximity to, the label(s) shall include content required in Sections 8.4.2.1 or 8.4.2.2 2 of this Section 8.4.2 . 8.4.2.1 Owner - Occupied Maintenance For systems installed in individually owned and occupied dwellings or units where system maintenance and monitoring for continued effectiveness will be the responsibility of the owner, the primary label shall include: a) Date of installation; b) Maintenance and monitoring instructions, to include: 1. A description of the system monitors and actions to take if the system monitors indicate system degradation or failure, and 2. A recommendation to verify continued system effectiveness over time, such as: — a recommendation to conduct a radon test at least every 2 years, or — other monitoring procedures as specified in an OM&M plan for radon or chemical vapor intrusion systems; c) State and federal informational resources, to include websites or phone numbers; and d) The installer’s name, phone number and applicable certification/license identification. 8.4.2.2 Independent Maintenance Where system maintenance and monitoring are the responsibility of someone other than the occupant: a) Informational content on a primary label that is observable to building maintenance staff or occupants shall include: 1. A description of system monitor(s) or monitoring systems and, as applicable, actions to take if the system monitor indicates system degradation, and 2. The name and contact information of the party responsible for maintenance and repairs. b) The client shall be advised in writing that it is the responsibility of the client to ensure the current party who owns maintenance obligations is identified on, or in immediate proximity to, this primary label. c) The OM&M manual shall observe that it is incumbent upon current and future parties responsible for systemmaintenance and monitoring to keep this label up-to-date. 8.4.3 System equipment System equipment shall be marked or identified with a label title that portrays the system purpose, such as “Radon Reduction System” or "Soil Gas Control System." The labeling shall also comply with requirements in a), b) and c) of this Section 8.4.3 . a) Mechanical Equipment ASD fans and other system air handling and mechanical equipment shall be labeled. RADON REDUCTION SYSTEM Installed: ___________ WC” ____ Maintenance (1) Routinely Check Pressure Gauge The fan is active if oil level on the left is different from the right. If the fan appears to be off: √ Check hose connection on gauge √ Check electrical (switch or breaker) √ If still indicating a problem, call for service. (2) Retest for radon every 2 years For Service: 1- 800-RN2-2222 R. Smith RPP# 54321 Health Department Contacts: www.epa.gov/radon; the radon hotline 1- 800-SOS-RADON (Persons with hearing or speech difficulties should call 711.); or at www.epa.gov/radon/find-information- about-local-radon-zones-and-state-contact- information RADON REDUCTION SYSTEM System Fan Monitor The system fan is active if oil level on the left is different from the right. Please call to report if the fan appears to be off. This system is under the care of: R. Smith, L.L.C 1-800-RN2-2222 Fig. 8.4.2.1 Example Fig. 8.4.2.2 Example
Made with FlippingBook
RkJQdWJsaXNoZXIy MTgwNDgx