CC-1000_2018

CC-1000 Companion Guidance (1-2018) CC-1000 Companion Guidance CG Page of 12 Informational 12 ANNEXES CC-1000 Discussion ANNEX A (Non-Normative) Inspections for compliance Any or all of the following inspections can be required by ordinance, contract or design specifications: A-1 Inspection prior to closure over soil by concrete or soil gas retarders for design, proper materials and secure fastening. A-2 Inspection prior to indoor finishings to verify plenum sealing and closure. A-3 Inspection prior to completion of indoor finishings to verify exhaust vent pipe compliance. ANNEX B (Non-Normative) ASD fans Fan installation can be required by ordinance, contract or design specifications. ANNEX C (Non-Normative) Radon test kits Ordinances, contracts or design specifications can require that radon test kits be provided as a tool to help verify occupant health and safety. ANNEX D (Non-Normative) Testing prior to occupancy Ordinances, contracts or design specifications can require testing prior to occupancy to help verify occupant health and safety. EXAMPLES OF COMMON FAN SIZES FOR ESTIMATING MINIMUM COSTS WHEN ACTIVATING SYSTEMS PIPE SIZE Nominal (I.D.) TOTAL AREA OF THE SOIL GAS COLLECTION PLENUM Less Than 1600 sq. ft. (149 m 2 ) 1600 to 2500 sq. ft. (149m 2 to 232m 2 ) 2500 to 4500 sq. ft. (232m 2 to 418m 2 ) 4000 to 10,000 sq. ft. (232m 2 to 929m 2 ) Minimum Fan Expected Minimum Fan Expected Minimum Fan Expected Minimum Fan Expected (3 inch) [7.6 cm] Fan Type: RF1 RF1 Minimum rating: 50 cfm @ 0.5 in. WC [85 m 3 /hr @ 125 Pa ] Fan Type: RF2 RF2 Minimum rating: 75 cfm @ 1.0 in. WC [127 m 3 /hr @ 250 Pa ] Fan Type: RF2 RF2 Minimum rating: 75 cfm @ 1.0 in. WC [127 m 3 /hr @ 250 Pa ] (4 inch) [10 cm] Fan Type: RF1 RF1 Minimum rating: 50 cfm @ 0.5 in. WC [85 m 3 /hr @ 125 Pa ] Fan Type: RF1 RF1 Minimum rating: 50 cfm @ 0.5 in. WC [85 m 3 /hr @ 125 Pa ] Fan Type: RF2 RF2 Minimum rating: 75 cfm @ 1.0 in. WC [127 m 3 /hr @ 250 Pa ] Fan Type: RF3 RF3 Minimum rating: 150 cfm @ 2.0 in. WC [254 m 3 /hr @ 500 Pa ] (6 inch) [15 cm] Fan Type: RF2 RF2 Minimum rating: 75 cfm @ 1.0 in. WC [127 m 3 /hr @ 250 Pa Fan Type: RF3 RF3 Minimum rating: 150 cfm @ 2.0 in. WC [254 m 3 /hr @ 500 Pa ] Radon Fan Types RF1, RF2 & RF3 minimum flow and pressure ratings are examples of manufacturer specifications. Fans needed are best determined by PFE evaluations described in Section 7 that are conducted after construction. For fans serving larger expanses or resistive soil gas transfer, both airflow capacity (cfm or m 3 /hr) and vacuum capacity (WC or pa) will often require additional capacity.

RkJQdWJsaXNoZXIy MTgwNDgx